Effect of Cement Type and Surface Modifications on Retention and Titanium Surface Stability in Implant Crowns
DOI:
https://doi.org/10.58600/eurjther3072Keywords:
ANOVA, computer-aided design and computer-aided manufacturing, dental cements, dental crowns, prostheses and implants, scanning electron microscopyAbstract
Objective: The aim of this study was to evaluate the effects of different cement types and surface treatments on retention, to assess the impact of mechanical loading and thermocycling on retention, and to examine the resulting surface alterations.
Methods: A total of 120 abutment analogs were prepared for full metal crowns. A total of 40 crowns were randomly cemented with four cements without surface treatment and tested for retention. Selected specimens were examined using scanning electron microscopy (SEM). All specimens underwent mechanical loading and thermal cycling, followed by retention testing and SEM analysis. In the experimental groups, internal crown surfaces were sandblasted or diamond-burr roughened prior to aging and retention testing. Retention data were analyzed using one-way ANOVA and Tukey's honestly significant difference (HSD) tests (α = 0.05).
Results: Permanent cements showed significantly higher retention than temporary cements across all treatments, with no differences within cement groups. Surface treatment did not significantly affect retention, and no statistically significant differences were observed between non-aged and aged specimens under the applied aging protocol. SEM revealed no observable morphological changes on the titanium surfaces before and after aging. Predominantly adhesive failures were observed, whereas both adhesive and cohesive failures were observed for Panavia SA. Air bubbles were present in manually mixed cements but absent in automix-prepared cements.
Conclusion: Cement type significantly affects retention of implant-supported crowns. Aging and crown surface roughening do not significantly influence retention, and no chemical changes were observed on titanium surfaces.
References
[1] Mehl C, Harder S, Wolfart M, Kern M, Wolfart S (2008) Retrievability of implant-retained crowns following cementation. Clin Oral Implants Res. 19(12):1304–1311. https://doi.org/10.1111/j.1600-0501.2008.01587.x
[2] Vigolo P, Givani A, Majzoub Z, Cordioli G (2006) A 4-year prospective study to assess peri-implant hard and soft tissues adjacent to titanium versus gold-alloy abutments in cemented single implant crowns. J Prosthodont. 15(4):250–256. https://doi.org/10.1111/J.1532-849X.2006.00114.X
[3] Reda R, Zanza A, Cicconetti A, Bhandi S, Guarnieri R, Testarelli L, Di Nardo D (2022) A systematic review of cementation techniques to minimize cement excess in cement-retained implant restorations. Methods Protoc. 5(1):9. https://doi.org/10.3390/mps5010009
[4] Fiorillo L, D’Amico C, Ronsivalle V, Cicciù M, Cervino G (2024) Single Dental Implant Restoration: Cemented or Screw-Retained? A Systematic Review of Multi-Factor Randomized Clinical Trials. Prosthesis. 6(4):871–886. https://doi.org/10.3390/PROSTHESIS6040063
[5] Mehta S, Kesari A, Tomar M, Gupta R, Singh V (2023) An Evaluation of the Effectiveness of Various Luting Cements on the Retention of Implant-Supported Metal Crowns. Cureus. 15(7):e41691. https://doi.org/10.7759/cureus.41691
[6] Lugas AT, Terzini M, Zanetti EM, Schierano G, Manzella C, Baldi D, Bignardi C, Audenino AL (2020) In Vitro Impact Testing to Simulate Implant-Supported Prosthesis Retrievability in Clinical Practice: Influence of Cement and Abutment Geometry. Materials. 13(7):1749. https://doi.org/10.3390/ma13071749.
[7] Pjetursson BE, Asgeirsson AG, Zwahlen M, Sailer I (2014) Improvements in implant dentistry over the last decade: Comparison of survival and complication rates in older and newer publications. Int J Oral Maxillofac Implants. 29(Suppl):308–324. https://doi.org/10.11607/jomi.2014suppl.g5.2
[8] Kokubo Y, Kano T, Tsumita M, Sakurai S, Itayama A, Fukushima S (2010) Retention of zirconia copings on zirconia implant abutments cemented with provisional luting agents. J Oral Rehabil. 37(1):48–53. https://doi.org/10.1111/j.1365-2842.2009.02013.x
[9] Dudley JE, Richards LC, Abbott JR (2008) Retention of cast crown copings cemented to implant abutments. Aust Dent J. 53(4):332–339. https://doi.org/10.1111/j.1834-7819.2008.00075.x
[10] Akça K, İplikçioğlu H, Çehreli MC (2002) Comparison of uniaxial resistance forces of cements used with implant-supported crowns. Int J Oral Maxillofac Implants. 17:536–542.
[11] Heinemann F, Mundt T, Biffar R. (2006) Retrospective evaluation of temporary cemented, tooth and implant supported fixed partial dentures. J Craniomaxillofac Surg. 34(Suppl 2):86–90. https://doi.org/10.1016/S1010-5182(06)60019-X
[12] Sahu N, Lakshmi N, Azhagarasan NS, Agnihotri Y, Rajan M, Hariharan, R (2014) Comparison of the effect of implant abutment surface modifications on retention of implant-supported restoration with a polymer-based cement. J Clin Diagn Res. 8:239. https://doi.org/10.7860/JCDR/2014/7877.3931
[13] Mansour A, Ercoli C, Graser G, Tallents R, Moss M (2002) Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin Oral Implants Res. 13:343–348. https://doi.org/10.1034/j.1600-0501.2002.130401.x
[14] Ramp MH, Dixon DL, Ramp LC, Breeding LC, Barber LL (1999) Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent. 81(5):510–514. https://doi.org/10.1016/s0022-3913(99)70203-9
[15] Covey DA, Kent DK, St Germain HA, Koka S (2000) Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns. J Prosthet Dent. 83(3):344–348. https://doi.org/10.1016/s0022-3913(00)70138-7
[16] Cameron SM, Morris WJ, Keesee SM, Barsky TB, Parker MH (2006) The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading. J Prosthet Dent. 95(6):456–461. https://doi.org/10.1016/j.prosdent.2006.03.021
[17] Edelhoff D, Özcan M (2007) To what extent does the longevity of fixed dental prostheses depend on the function of the cement? Working Group 4 Materials: Cementation. Clin Oral Implants Res. 18(Suppl 3):193–204. https://doi.org/10.1111/j.1600-0501.2007.01442.x.
[18] Proussaefs P, Campagni W, Bernal G, Goodacre C, Kim J (2004) The effectiveness of auxiliary features on a tooth preparation with inadequate resistance form. J Prosthet Dent. 91(1):33–41. https://doi.org/10.1016/j.prosdent.2003.10.005
[19] Kim Y, Yamashita J, Shotwell JL, Chong KH, Wang HL (2006) The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns. J Prosthet Dent. 95(6):450–455. https://doi.org/10.1016/j.prosdent.2006.03.020
[20] Varalakshmi Reddy S, Sushender Reddy M, Rajaneesh Reddy C, Pithani P, Santosh Kumar R, Kulkarni G (2015) The Influence of Implant Abutment Surface Roughness and the Type of Cement on Retention of Implant Supported Crowns. J Clin Diagn Res. 9(3):ZC05-ZC08. https://doi.org/10.7860/JCDR/2015/12060.5621
[21] Ozyetim E, Ozdemir Z, Basim G, Bayraktar G (2023) Effect of Different Surface Treatments on Retention of Cement-Retained, Implant-Supported Crowns. Int J Prosthodont. 36(1):30–36. https://doi.org/10.11607/IJP.6602
[22] Sadig WM, Al Harbi MW (2007) Effects of surface conditioning on the retentiveness of titanium crowns over short implant abutments. Implant Dent. 16(4):387–396. https://doi.org/10.1097/ID.0B013E31815C8D7B
[23] Alvarez-Arenal A, Gonzalez-Gonzalez I, de Llanos-Lanchares H, Brizuela-Velasco A, Ellacuria-Echebarria J (2016) The selection criteria of temporary or permanent luting agents in implant-supported prostheses: In vitro study. J Adv Prosthodont. 8(2):144–149. https://doi.org/10.4047/JAP.2016.8.2.144
[24] GaRey DJ, Tjan AHL, James RA, Caputo AA (1994) Effects of thermocycling, load-cycling, and blood contamination on cemented implant abutments. J Prosthet Dent. 71(2):124–132. https://doi.org/10.1016/0022-3913(94)90019-1
[25] Michalakis KX, Pissiotis AL, Kang K, Hirayama H, Garefis PD, Petridis HP (2007) The Effect of Thermal Cycling and Air Abrasion on Cement Failure Loads of 4 Provisional Luting Agents Used for the Cementation of Implant-Supported Fixed Partial Dentures. Int J Oral Maxillofac Implants. 22(4):569–574.
[26] Veselinović V, Marin S, Tatić Z, Trtić N, Dolić O, Adamović T, Arbutina R, Šćepanović M, Todorović A (2021) Application of Semipermanent Cements and Conventional Cement with Modified Cementing Technique in Dental Implantology. Acta Stomatol Croat. 55(4):367–379. https://doi.org/10.15644/ASC55/4/4
[27] Güncü MB, Çakan U, Canay Ş (2011) Comparison of 3 luting agents on retention of implant-supported crowns on 2 different abutments. Implant Dent. 20(5):349–353. https://doi.org/10.1097/ID.0B013E318225F68E
[28] Carnaggio TV, Conrad R, Engelmeier RL, Gerngross P, Paravina R, Perezous L, Powers JM (2012) Retention of CAD/CAM all-ceramic crowns on prefabricated implant abutments: An in vitro comparative study of luting agents and abutment surface area. J Prosthodont. 21(7):523–528. https://doi.org/10.1111/j.1532-849X.2012.00847.x
[29] Kunt GE, Ceylan G, Yilmaz N, Küçük BE (2014) Luting Agent Effectiveness on Implant Crown Retention. Int J Oral Implantol Clin Res. 2(1):7–11. https://doi.org/10.5005/jp-journals-10012-1029
[30] Bajoghli F, Fathi A, Ebadian B, Jowkar M, Sabouhi M (2023) The effect of different methods of cleansing temporary cement (with and without eugenol) on the final bond strength of implant-supported zirconia copings after final cementation: An in vitro study. Dent Res J (Isfahan). 20(1):22. https://doi.org/10.4103/1735-3327.369624
[31] Lambrechts P, Debels E, Van Landuyt K, Peumans M, Van Meerbeek B (2006) How to simulate wear? Overview of existing methods. Dent Mater. 22(8):693–701. https://doi.org/10.1016/j.dental.2006.02.004
[32] Prause E, Hey J, Beuer F, Rosentritt M (2022) Factors influencing retention of resin-based luting systems on implants: A systematic review. Dentistry Review. 2(3):100056. https://doi.org/10.1016/j.dentre.2022.100056
[33] Abu-Obaid A (2024) Effects of cementation technique and cement thickness on the retention and amount of excess cement in implant-supported restorations. Saudi Dent J. 36(9):1203–1208. https://doi.org/10.1016/j.sdentj.2024.06.018
[34] Misch CE, Goodacre CJ, Finley JM, Misch CM, Marinbach M, Dabrowsky T, English CE, Kois JC, Cronin RJ Jr (2005) Consensus conference panel report: Crown-height space guidelines for implant dentistry-Part 1. Implant Dent. 14(4):312–321. https://doi.org/10.1097/01.ID.0000188375.76066.23
[35] Ghodsi S, Shekarian M, Aghamohseni MM, Rasaeipour S, Arzani S (2023) Resin cement selection for different types of fixed partial coverage restorations: A narrative systematic review. Clin Exp Dent Res. 9(6):1096–1111. https://doi.org/10.1002/CRE2.761
[36] Squier RS, Agar JR, Duncan JP, Taylor TD (2001) Retentiveness of dental cements used with metallic implant components. Int J Oral Maxillofac Implants. 16(6):793–798.
[37] Garg P, Gupta G, Prithviraj D, Pujari M (2013) Retentiveness of various luting agents used with implant-supported prostheses: a preliminary in vitro study. Int J Prosthodont. 26(1):82–84. https://doi.org/10.11607/IJP.2572
[38] Sarfaraz H, Hassan A, Kamalakanth Shenoy K, Shetty M (2019) An in vitro study to compare the influence of newer luting cements on retention of cement-retained implant-supported prosthesis. J Indian Prosthodont Soc. 19(2):166–172. https://doi.org/10.4103/JIPS.JIPS_235_18
[39] Hendi A, Falahchai M, Sigaroodi SH, Asli HN (2023) Comparison of marginal leakage and retentive strength of implant supported milled zirconia and cobalt chromium copings cemented with different temporary cements. Dent Res J (Isfahan). 20(1). https://doi.org/10.4103/DRJ.DRJ_344_23
[40] Mehl C, Scheibner S, Ludwig K, Kern M (2007) Wear of composite resin veneering materials and enamel in a chewing simulator. Dent Mater. 23(11):1382–1389. https://doi.org/10.1016/j.dental.2006.11.026
[41] Pan YH, Ramp LC, Lin CK, Liu PR (2006) Comparison of 7 luting protocols and their effect on the retention and marginal leakage of a cement-retained dental implant restoration. Int J Oral Maxillofac Implants. 21(4):587–592.